with connection head
Resistance thermometers for shipbuilding application (GL)
Resistance thermometers with explosion proof
Special types
Measuring inserts
Precision resistance thermometer
Cable sensors
product | representation | sensor* | thermowell material | application temperature | process connection |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
-40°C to +85°C |
holes for wall mounting |
|
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
-35 °C to +100 °C |
\\Hyphenation{Ein-stech"~Wider-stands-thermo-meter} |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
-200 to +600°C up to +380°C for GL-Design |
without; adjustable thread joint M20x1,5, G1/2A, M27x2, G3/4A; combination protective tube M27x2, G3/4A |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -200 to +600°C up to +380°C for GL-Design -50 to +400°C |
without, Stop flange 15 oder adjustable thread joint |
![]() |
![]() |
1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 |
1.4571 Brass |
0 °C to 60 °C 0 °C to 120 °C 0 °C to 200 °C |
Combination of resistance and glass thermometer |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -200 to +600°C -50 to +400°C |
cap nut or screw-in sleeve M20x1,5; G1/2; M18x1,5; M27x2; G3/4 |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
-40 °C to +90 °C |
Room resistance thermometer inside a plastic case |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
-40 °C to +120 °C |
Room resistance thermometer inside a metal case |
![]() |
![]() |
1xPt 100 selected |
1.4571 |
0 °C to 200 °C 0 °C to 140 °C |
Resistance heatmeter |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -200 to +600°C up to +380°C for GL-Design -50 to +400°C |
fix threaded joint M20x1,5; G1/2A; M27x2; G3/4A |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry 1.0460 (C22.8) |
on inquiry -200 to +600°C up to +380°C for GL-Design -50 to +400°C |
for welding in |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
-200 to +600°C up to +380°C for GL-Design |
fix threaded joint M20x1,5; G1/2A; M27x2; G3/4A |
![]() |
![]() |
1xPt 100 cl. W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
-200 to +600°C up to +380°C for GL-Design |
fix threaded joint M20x1,5; G1/2A |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -200 to +600°C -50 to +400°C |
for laboratory work or for built-in fittings |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 |
on inquiry -200 to +600°C -50 to +400°C |
for laboratory purposes |
![]() |
![]() |
1xPt 100 selected |
1.4571 |
0 °C to 200 °C 0 °C to 140 °C |
for laboratory purposes
|
![]() |
![]() |
1xPt 100 cl. W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -200 to +600°C -50 to +400°C |
for laboratory purposes or or built-in protective fittings |
![]() |
![]() |
1xPt 500 cl. B acc. to DIN EN 60751 1xPt 1000 cl. B acc. to DIN EN 60751 1xPt 100 cl. B acc. to DIN EN 60751 1xNi 100 cl. B acc. to DIN EN 43760 1xNi 500 cl. B acc. to DIN EN 43760 1xNi 1000 cl. B acc. to DIN 43760 on inquiry |
Cu tube blank Cu tube with heat shrink hose covered ( only up to 140°C) |
for Pt: -40 °C to +140 °C for Pt: -40 °C to +350 °C for Ni: -40 °C to + 140 °C for Ni: - 40 °C to + 250 °C |
without |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -200 to +600°C up to +380°C for GL-Design -50 to +400°C |
fix threaded joint M20x1,5; G1/2A |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -200 to +600°C -50 to +400°C |
fix threaded joint M20x1,5; G1/2A |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -200 to +600°C -50 to +400°C |
flange welded on protective tube d1, d2 and b according DIN or on inquire |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
-50 up to +300°C -200 up to +300°C |
fix threaded joint M18x1,5; M20x1,5; G1/2A |
![]() |
![]() |
1xPt 100 cl. W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -200 to +600°C -50 to +400°C |
without |
![]() |
![]() |
1xPt 100 cl. W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4541 1.4571 |
-200 to +600°C -200 to +850°C |
without |
![]() |
![]() |
1xPt 100 selected |
1.4571 |
0 °C to 140 °C |
Resistance heatmeter |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -50 up to +400°C (max. 120°C near the connector) |
fix threaded joint G1/2A |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -50 up to +400°C (max. 85°C near the transmitter) |
solid threaded joint G1/2A |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -50 up to +400°C (max. 85°C near the transmitter) |
solid threaded joint G1/2A |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -50 up to +400°C (max. 85°C near the transmitter) |
solid threaded joint G1/2A |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -50 up to +400°C (max. 85°C near the transmitter) |
Small resistance thermometer for screwing in |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry -50 up to +400°C (max. 85°C near the connector) |
fix threaded joint M20x1,5; G1/2A |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry 1xPt 500 cl. F0,3 (old cl. B) acc. to DIN EN 60751 |
1.4571 |
-30 °C to +80 °C | Fixing with magnet |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 |
-30 °C to +80 °C | Fixing with magnet |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 |
-30 °C to +80 °C | Fixing with magnet |
![]() |
![]() |
HL-sensor |
-30 °C to +85 °C |
holes for wall mounting; |
|
![]() |
![]() |
HL-sensor |
-30 °C to +85 °C |
holes for wall mounting; |
|
![]() |
![]() |
Pt100 |
1.4571 stainless steel |
Precision resistance thermometer |
|
![]() |
![]() |
Pt100 |
1.4571 stainless steel |
Precision resistance thermometer for high temperature |
|
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry, dependent on sensor and protective tube material |
without |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
on inquiry stainless steel |
on inquiry, dependent on sensor and protective tube material |
Thread such as M8 for srewing in |
![]() |
![]() |
1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry, dependent on sensor and protective tube material |
fix threaded joint such as G3/4A |
![]() |
![]() |
1xPt 100 selected |
1.4571 |
0 °C to 140 °C |
Thread G1/2A |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry, dependent on sensor and protective tube material |
adjustable threaded joint such as M10x1 |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry, dependent on sensor and protective tube material |
adjustable threaded joint such as M10x1 |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
1.4571 on inquiry |
on inquiry, dependent on sensor and protective tube material |
lock nut such as G1/2 |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
on inquiry 1.4305 |
on inquiry, dependent on sensor and protective tube material |
bajonet lock cap, suitable threaded nipple available |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
on inquiry stainless steel Brass aluminium |
on inquiry, dependent on sensor and protective tube material |
without or drilling for screw M4 in protective case |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
on inquiry stainless steel Brass |
on inquiry, dependent on sensor and protective tube material |
Clamping band with clamping rang 10 ... 190 mm ( >100 mm clamping band enclosed) |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
on inquiry stainless steel |
on inquiry, dependent on sensor and protective tube material |
without |
![]() |
![]() |
1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751 1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751 on inquiry |
without |