In-Head Transmitter LKM 141
Thermocouples, J-head, 4..20mA, 24V supply voltage
The LKM 141 is an analogue transducer for thermo couples acc. DIN EN 60584 or DIN 43713.
The temperature-sensitiv voltage will be transformed into an analogue current output of 4..20mA.
The LKM 141 can be mounted inside the protection head type J.
The span needs at least a range of 200°C.
The transducer LKM 141 is tuned ex works according to the customized requires. Further fine-tuning can be arranged by span and zero controller.
Input
thermocouple K, J(L), T(U), N, E;
S B with higher fault
Output
4...20mA current loop
Range
> 200°C*
Zero point
> -270°C*
Loop voltage
10...35VDC, reverse protection
Sensor fracture
>20 mA
Shorted Sensor
ambient temperature
Permissible ripple
< 10 %
Reaction time
< 0.1s
Vibration
5g/10-200Hz
Linearity error
<0.1% FS*
Error of compensation
<±0.5°C
TCR
<100ppm/°C
Operating temperature range
-25°C ... +85°C
Terminal type
screw terminal
Clamping range
0.13...0.75mm²
Humidity
< 95%
EMC emission
EN 61000-6-3:2001
EMC interference rejection ratio
EN 61000-6-3:2001
Mounting
J-head
Dimension
25mm x 14 mm (DxH)
Sealing compound
Polyurethan, black
Weight
approx. 10g
* dependent upon thermocouple