Product cataloque > Product cataloque > Product overview > Cable sensors  > With attaching parts
product summary With attaching parts
 
 
product representationsensor*thermowell materialapplication temperatureprocess connection
K4T 

J (Fe-CuNi) DIN EN 60584

K (NiCr-Ni) DIN EN 60584

on inquiry

on inquiry

stainless steel

on inquiry, dependent on sensor and protective tube material

Thread such as M8 for srewing in

K5T 

J (Fe-CuNi) DIN EN 60584

K (NiCr-Ni) DIN EN 60584

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

fix threaded joint such as G3/4A

K6T 

J (Fe-CuNi) DIN EN 60584

K (NiCr-Ni) DIN EN 60584

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

adjustable threaded joint such as M10x1

K7T 

J (Fe-CuNi) DIN EN 60584

K (NiCr-Ni) DIN EN 60584

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

adjustable threaded joint such as M10x1

K8T 

J (Fe-CuNi) DIN EN 60584

K (NiCr-Ni) DIN EN 60584

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

lock nut such as G1/2

K9T 

J (Fe-CuNi) DIN EN 60584

K (NiCr-Ni) DIN EN 60584

on inquiry

on inquiry

1.4305

on inquiry, dependent on sensor and protective tube material

bajonet lock cap, suitable threaded nipple available

K11T 

J (Fe-CuNi) DIN EN 60584

K (NiCr-Ni) DIN EN 60584

on inquiry

on inquiry

stainless steel

Brass

on inquiry, dependent on sensor and protective tube material

Clamping band with clamping rang 10 ... 190 mm ( >100 mm clamping band enclosed)

K4W 

1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

on inquiry

on inquiry

stainless steel

on inquiry, dependent on sensor and protective tube material

Thread such as M8 for srewing in

K5W 

1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751

1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751

2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751

2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

fix threaded joint such as G3/4A

K5WZ 

1xPt 100 selected

1.4571

0 °C to 140 °C

Thread G1/2A

K6W 

1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

adjustable threaded joint such as M10x1

K7W 

1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

adjustable threaded joint such as M10x1

K8W 

1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

lock nut such as G1/2

K9W 

1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

on inquiry

on inquiry

1.4305

on inquiry, dependent on sensor and protective tube material

bajonet lock cap, suitable threaded nipple available

K11W 

1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

on inquiry

on inquiry

stainless steel

Brass

on inquiry, dependent on sensor and protective tube material

Clamping band with clamping rang 10 ... 190 mm ( >100 mm clamping band enclosed)

Last Updated: